Name | Type | Description |
Reference |
P_SINGLEVALUE
/
IfcIdentifier
|
| Reference | Reference ID for this specified type in this project (e.g. type 'A-1'), provided, if there is no classification reference to a recognized classification system used. |
| 参照 | 当該プロジェクトで定義する形式の参照ID(例:A-1)、承認された分類に存在しないときに使用される。 |
|
Status |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_ElementStatus |
| Status | Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure). |
| 状態 | 要素(主にリノベーションまたは改修プロジェクトにおいて)の状態。 状態は、「新規(New)」-新しく追加される要素。「既存」-要素は存在し、かつ残りもの。「破壊」-要素は存在したが、廃棄されるもの。「一時的」-一時的に存在する要素(一時的にサポートしている構造のようなもの)。 |
|
NumberOfSources |
P_SINGLEVALUE
/
IfcInteger
|
| Number Of Sources | Number of sources . |
| 電球数 | 電球数。 |
| 전구수 | 전구수 |
|
TotalWattage |
P_SINGLEVALUE
/
IfcPowerMeasure
|
| Total Wattage | Wattage on whole lightfitting device with all sources intact. |
| 総ワット数 | 全ての照明器具のワット数。 |
| 총 와트 | 모든 조명기구 와트. |
|
LightFixtureMountingType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_LightFixtureMountingType |
| Light Fixture Mounting Type | A list of the available types of mounting for light fixtures from which that required may be selected. |
| 照明器具取付方法 | 照明器具の取付方法をリストから選択。 |
| 조명기구 설치방법 | 조명기구의 설치 방법을 목록에서 선택합니다. |
|
LightFixturePlacingType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_LightFixturePlacingType |
| Light Fixture Placing Type | A list of the available types of placing specification for light fixtures from which that required may be selected. |
| 照明器具取付場所 | 照明器具の取付場所をリストから選択。 |
| 조명기구 설치 장소 | 조명기구의 설치 장소를 목록에서 선택합니다. |
|
MaintenanceFactor |
P_SINGLEVALUE
/
IfcReal
|
| Maintenance Factor | The arithmetical allowance made for depreciation of lamps and reflective equipment from their initial values due to dirt, fumes, or age. |
| 保守率 | 汚れ、煙、年数による初期からのランプや反射装置の低減許容計算。 |
| 보수 비율 | 먼지, 연기, 연수의 초기부터 램프와 반사 장치의 저감 허용 계산. |
|
MaximumPlenumSensibleLoad |
P_SINGLEVALUE
/
IfcPowerMeasure
|
| Maximum Plenum Sensible Load | Maximum or Peak sensible thermal load contributed to return air plenum by the light fixture. |
|
MaximumSpaceSensibleLoad |
P_SINGLEVALUE
/
IfcPowerMeasure
|
| Maximum Space Sensible Load | Maximum or Peak sensible thermal load contributed to the conditioned space by the light fixture. |
|
SensibleLoadToRadiant |
P_SINGLEVALUE
/
IfcPositiveRatioMeasure
|
| Sensible Load To Radiant | Percent of sensible thermal load to radiant heat. |
|