Name | Type | Description |
People |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| People | Heat gains and losses from people. |
| 人員 | 人員からの熱取得。 |
| 인원 | 사람의 열 |
|
Lighting |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Lighting | Lighting loads. |
| 照明 | 照明負荷。 |
| 조명 | 조명 부하 |
|
EquipmentSensible |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Equipment Sensible | Heat gains and losses from equipment. |
| 事務機器の顕熱 | 事務機器からの熱取得と熱ロス。 |
| 사무기기의 현열 | 사무기기에서 열 취득 및 손실 |
|
VentilationIndoorAir |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Ventilation Indoor Air | Ventilation loads from indoor air. |
| 室内の換気量 | 室内の換気による熱負荷。 |
| 실내 환기량 | 실내 환기에 의한 열 부하 |
|
VentilationOutdoorAir |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Ventilation Outdoor Air | Ventilation loads from outdoor air. |
| 外気量 | 外気による熱負荷。 |
| 외기량 | 외기에한 열부하 |
|
RecirculatedAir |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Recirculated Air | Loads from recirculated air. |
| 循環空気 | 循環空気による熱負荷。 |
| 순환공기 | 순환공기에 의한 열부하 |
|
ExhaustAir |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Exhaust Air | Loads from exhaust air. |
| 排気 | 排気による熱負荷。 |
| 배기 | 배기에 의한 열부하 |
|
AirExchangeRate |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Air Exchange Rate | Loads from the air exchange rate. |
| 換気回数 | 換気による熱負荷。 |
| 환기회수 | 환기에 의한 열부하 |
|
DryBulbTemperature |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Dry Bulb Temperature | Loads from the dry bulb temperature. |
| 乾球温度 | 乾球温度による熱負荷。 |
| 건구온도 | 건구온도에의한 열부하 |
|
RelativeHumidity |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Relative Humidity | Loads from the relative humidity. |
| 相対湿度 | 相対湿度による熱負荷。 |
| 상대습도 | 상대습도에 의한 열부하 |
|
InfiltrationSensible |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Infiltration Sensible | Heat gains and losses from infiltration. |
| すき間風の顕熱 | すき間風からの熱負荷と熱ロス。 |
| 열취득 및 손실 | 열 부하및 열손실 |
|
TotalSensibleLoad |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Total Sensible Load | Total energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space. |
| 顕熱負荷の合計 | 空気温度を上昇・下降させる取得・損失の熱量の合計。ゼロより小さい(-)場合、室内が熱損失となる。ゼロより大きい(+)場合、室内が熱取得となる。 |
| 현열부하의 합계 | 공기 온도를 상승 · 하강하는 취득 · 손실 열량의 총. 제로보다 작은 (-) 경우 실내가 열 손실이된다. 제로보다 큰 (+) 경우 실내가 열을 검색된다. |
|
TotalLatentLoad |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Total Latent Load | Total energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space. |
| 潜熱負荷の合計 | 空気湿度(水蒸気量)を上昇・下降させる取得・損失の熱量の合計。ゼロより小さい(-)場合、室内の水蒸気が減少となる。ゼロより大きい(+)場合、室内の水蒸気が増大となる。 |
| 잠열부하의 합계 | 습도 (수증기량)을 상승 · 하강하는 취득 · 손실 열량의 총. 제로보다 작은 (-) 경우 실내의 수증기가 감소된다. 제로보다 큰 (+) 경우 실내의 수증기가 증가된다. |
|
TotalRadiantLoad |
P_BOUNDEDVALUE
/
IfcPowerMeasure
|
| Total Radiant Load | Total electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space. |
| 放射熱負荷の合計 | 放射や吸収による放射エネルギーの増加、或いは減少の合計。ゼロより小さい(-)場合、放射エネルギーが減少となる。ゼロより大きい(+)場合、放射エネルギーが増大となる。 |
| 복사열로드 합계 | 방사선 및 흡수에 의한 방사 에너지 증가 또는 감소의 총. 제로보다 작은 (-) 경우 방사 에너지가 감소된다. 제로보다 큰 (+) 경우 방사 에너지가 증대된다. |
|