7.8.4.1 Pset_ConcreteElementGeneral

PSET_TYPEDRIVENOVERRIDE / IfcBeam,IfcBuildingElementProxy,IfcChimney,IfcColumn,IfcFooting,IfcMember,IfcPile,IfcPlate,IfcRailing,IfcRamp,IfcRampFlight,IfcRoof,IfcSlab,IfcStair,IfcStairFlight,IfcWall,IfcCivilElement

Natural language names
Concrete Element General
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
ConstructionMethod P_SINGLEVALUE / IfcLabel
Ausf眉hrungAngabe, ob dieses Betonbauteil als Ortbeton ("In-Situ") oder als Fertigteil ("Precast") ausgef眉hrt werden soll.
Construction MethodDesignator for whether the concrete element is constructed on site or prefabricated. Allowed values are: 'In-Situ' vs 'Precast'.
StructuralClass P_SINGLEVALUE / IfcLabel
Structural ClassThe structural class defined for the concrete structure (e.g. '1').
妲嬮犮偗銉┿偣妲嬮犮偗銉┿偣銇偝銉炽偗銉兗銉堟閫犮倰瀹氱京銇椼仧銆傦紙渚嬨亪銇般岋紤銆嶏級
StrengthClass P_SINGLEVALUE / IfcLabel
BetonfestigkeitsklasseKlassifikation der Betonfestigkeit gem盲脽 der aktuellen, im Projekt angewandten, Norm.
Strength ClassClassification of the concrete strength in accordance with the concrete design code which is applied in the project.
ExposureClass P_SINGLEVALUE / IfcLabel
ExpositionsklasseKlassifikation der Widerstandsf盲higkeit gegen眉ber chemischen und physikalischen Einwirkungen gem盲脽 der aktuellen, im Projekt angewandten, Norm.
Exposure ClassClassification of exposure to environmental conditions, usually specified in accordance with the concrete design code which is applied in the project.
ReinforcementVolumeRatio P_SINGLEVALUE / IfcMassDensityMeasure
Bewehrungsgrad VolumenDas geforderte Verh盲ltnis der effektiven Masse der Bewehrung im Verh盲ltnis zur effektiven Masse des Betons f眉r dieses Element.
Reinforcement Volume RatioThe required ratio of the effective mass of the reinforcement to the effective volume of the concrete of a reinforced concrete structural element.
ReinforcementAreaRatio P_SINGLEVALUE / IfcAreaDensityMeasure
Bewehrungsgrad Fl盲cheDas geforderte Verh盲ltnis der effektiven fl盲chenbezogenen Masse der Bewehrung im Verh盲ltnis zur effektiven Fl盲che des Betons f眉r dieses Element.
Reinforcement Area RatioThe required ratio of the effective area of the reinforcement to the effective area of the concrete At any section of a reinforced concrete structural element.
DimensionalAccuracyClass P_SINGLEVALUE / IfcLabel
Dimensional Accuracy ClassClassification designation of the dimensional accuracy requirement according to local standards.
瀵告硶绮惧害銈儵銈鍥姐伄鍩烘簴銇屾眰銈併倠瀵告硶绮惧害銇垎椤炴寚瀹氥
ConstructionToleranceClass P_SINGLEVALUE / IfcLabel
Construction Tolerance ClassClassification designation of the on-site construction tolerances according to local standards.
瑁介犺ū瀹广偗銉┿偣鍥姐伄鍩烘簴銇屾眰銈併倠鐝惧牬銇с伄瑁介犺ū瀹广伄鍒嗛鎸囧畾銆
ConcreteCover P_SINGLEVALUE / IfcPositiveLengthMeasure
Beton眉berdeckungAbstand zwischen der Betonoberfl盲che und der Au脽enkante einer vom Beton umh眉llten Bewehrung.
Concrete CoverThe protective concrete cover at the reinforcing bars according to local building regulations.
ConcreteCoverAtMainBars P_SINGLEVALUE / IfcPositiveLengthMeasure
Beton眉berdeckung Hauptst盲beAbstand zwischen der Betonoberfl盲che und der Au脽enkante den vom Beton umh眉llten Bewehrungshauptst盲ben.
Concrete Cover At Main BarsThe protective concrete cover at the main reinforcing bars according to local building regulations.
涓荤瓔銇偝銉炽偗銉兗銉堣銈鍥姐伄寤虹瘔鍩烘簴銇緭銇勩佷富閴勭瓔銈掋偝銉炽偗銉兗銉堛伄琚倞銇т繚璀枫仚銈嬨
ConcreteCoverAtLinks P_SINGLEVALUE / IfcPositiveLengthMeasure
Beton眉berdeckung Verbindungsst盲beAbstand zwischen der Betonoberfl盲che und der Au脽enkante der vom Beton umh眉llten Bewehrungsverbindungsst盲ben.
Concrete Cover At LinksThe protective concrete cover at the reinforcement links according to local building regulations.
瑁滃挤绛嬨伄銈炽兂銈儶銉笺儓琚倞鍥姐伄寤虹瘔鍩烘簴銇緭銇勩佽寮风瓔銈掋偝銉炽偗銉兗銉堛伄琚倞銇т繚璀枫仚銈嬨
ReinforcementStrengthClass P_SINGLEVALUE / IfcLabel
Reinforcement Strength ClassClassification of the reinforcement strength in accordance with the concrete design code which is applied in the project. The reinforcing strength class often combines strength and ductility.

Link to this page  Link to this page