7.4.4.33 Pset_ElectricFlowStorageDeviceTypeCommon

PSET_TYPEDRIVENOVERRIDE / IfcElectricFlowStorageDevice

Natural language names
Electric Flow Storage Device Type Common
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
Reference P_SINGLEVALUE / IfcIdentifier *
BauteiltypBezeichnung zur Zusammenfassung gleichartiger Bauteile zu einem Bauteiltyp (auch Konstruktionstyp genannt). Alternativ zum Namen des "Typobjekts", insbesondere wenn die Software keine Typen unterst眉tzt.
ReferenceReference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types.
ReferenceR茅f茅rence 脿 l'identifiant d'un type sp茅cifi茅 dans le contexte du projet (exemple : "type A1") pour d茅signer un "type de construction". Une alternative au nom d'un objet type lorsque les objets types ne sont pas g茅r茅s par le logiciel.
鍙傜収瑷樺彿銇撱伄銉椼儹銈搞偋銈儓銇亰銇戙倠鍙傜収瑷樺彿(渚嬶細A-1)銆傚垎椤炪偝銉笺儔銇с伅銇亸鍐呴儴銇т娇鐢ㄣ仌銈屻倠銉椼儹銈搞偋銈儓銈裤偆銉椼仺銇椼仸浣跨敤銇曘倢銈嬨倐銇
鍙傝冨彿鑻ユ湭閲囩敤宸茬煡鐨勫垎绫荤郴缁燂紝鍒欒灞炴т负璇ラ」鐩腑璇ョ被鍨嬫瀯浠剁殑鍙傝冪紪鍙凤紙渚嬪锛岀被鍨婣-1锛夈
Status P_ENUMERATEDVALUE / IfcLabel / PEnum_ElementStatus*
StatusStatus bzw. Phase des Bauteils insbesondere beim Bauen im Bestand. "Neu" (new) neues Bauteil als Erg盲nzung, "Bestand" (existing) bestehendes Bauteil, dass erhalten bleibt, "Abbruch" (demolish) Bauteil, das abgebrochen wird, "Tempor盲r" (temporary) Bauteil und andere Bauelemente, die vor眉bergehend eingebaut werden (wie Abst眉tzungen, etc.)
StatusStatus of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).
StatutStatut de l'茅l茅ment, principalement utilis茅 dans les projets de r茅novation et de r茅habilitation. Le statut a pour valeur NOUVEAU pour un nouvel 茅l茅ment, EXISTANT pour un 茅l茅ment existant qui est conserv茅, DEMOLI pour un 茅l茅ment existant 脿 d茅molir et TEMPORAIRE pour un 茅l茅ment temporaire (comme une structure support provisoire).
鐘舵厠瑕佺礌锛堜富銇儶銉庛儥銉笺偡銉с兂銇俱仧銇敼淇儣銉偢銈с偗銉堛伀銇娿亜銇︼級銇姸鎱嬨 鐘舵厠銇併屾柊瑕(New)銆嶏紞鏂般仐銇忚拷鍔犮仌銈屻倠瑕佺礌銆傘屾棦瀛樸嶏紞瑕佺礌銇瓨鍦ㄣ仐銆併亱銇ゆ畫銈娿倐銇傘岀牬澹娿嶏紞瑕佺礌銇瓨鍦ㄣ仐銇熴亴銆佸粌妫勩仌銈屻倠銈傘伄銆傘屼竴鏅傜殑銆嶏紞涓鏅傜殑銇瓨鍦ㄣ仚銈嬭绱狅紙涓鏅傜殑銇偟銉濄兗銉堛仐銇︺亜銈嬫閫犮伄銈堛亞銇倐銇級銆
NominalSupplyVoltage P_SINGLEVALUE / IfcElectricVoltageMeasure
Nominal Supply VoltageThe nominal voltage of the supply.
鍏О闆诲湩闆绘簮銇叕绉伴浕鍦с
NominalSupplyVoltageOffset P_BOUNDEDVALUE / IfcElectricVoltageMeasure
Nominal Supply Voltage OffsetThe maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V.
銈儠銈汇儍銉堝叕绉伴浕鍦闆绘簮銇渶澶уゃ仺鏈灏忚ū瀹归浕鍦с傘仧銇ㄣ亪銇380V/440V銇鐣屻伅400V銇叕绉伴浕鍦с伀閬╃敤銇曘倢銈嬨
NominalFrequency P_SINGLEVALUE / IfcFrequencyMeasure
Nominal FrequencyThe nominal frequency of the supply.
鍏О鍛ㄦ尝鏁闆绘簮銇叕绉板懆娉㈡暟銆
ConnectedConductorFunction P_ENUMERATEDVALUE / IfcLabel / PEnum_ConductorFunctionEnum
Connected Conductor FunctionFunction of the conductors to which the load is connected.
鎺ョ稓灏庝綋姗熻兘灏庝綋銇鑳姐伅璨犺嵎銇屾帴缍氥仌銈屻仧鐘舵厠銆
ShortCircuit3PoleMaximumState P_SINGLEVALUE / IfcElectricCurrentMeasure
Short Circuit3 Pole Maximum StateMaximum 3 pole short circuit current provided at the point of supply.
3妤垫渶澶х煭绲¢浕娴闆绘簮渚涚郸鏅傜偣銇3妤垫渶澶х煭绲¢浕娴併
ShortCircuit3PolePowerFactorMaximumState P_SINGLEVALUE / IfcReal
Short Circuit3 Pole Power Factor Maximum StatePower factor of the maximum 3 pole short circuit current provided at the point of supply.
3妤垫渶澶х煭绲¢浕娴佸姏鐜闆绘簮渚涚郸鏅傜偣銇3妤垫渶澶х煭绲¢浕娴佸姏鐜囥
ShortCircuit2PoleMinimumState P_SINGLEVALUE / IfcElectricCurrentMeasure
Short Circuit2 Pole Minimum StateMinimum 2 pole short circuit current provided at the point of supply.
2妤垫渶灏忕煭绲¢浕娴闆绘簮渚涚郸鏅傜偣銇2妤垫渶灏忕煭绲¢浕娴併
ShortCircuit2PolePowerFactorMinimumState P_SINGLEVALUE / IfcReal
Short Circuit2 Pole Power Factor Minimum StatePower factor of the minimum 2 pole short circuit current provided at the point of supply.
2妤垫渶灏忕煭绲¢浕娴佸姏鐜闆绘簮渚涚郸鏅傜偣銇2妤垫渶灏忕煭绲¢浕娴佸姏鐜囥
ShortCircuit1PoleMaximumState P_SINGLEVALUE / IfcElectricCurrentMeasure
Short Circuit1 Pole Maximum StateMaximum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N.
1妤垫渶澶х煭绲¢浕娴闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺N闁撱伄1妤垫渶澶х煭绲¢浕娴併
ShortCircuit1PolePowerFactorMaximumState P_SINGLEVALUE / IfcReal
Short Circuit1 Pole Power Factor Maximum StatePower factor of the maximum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N.
1妤垫渶澶х煭绲¢浕娴佸姏鐜闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺N闁撱伄1妤垫渶澶х煭绲¢浕娴佸姏鐜囥
ShortCircuit1PoleMinimumState P_SINGLEVALUE / IfcElectricCurrentMeasure
Short Circuit1 Pole Minimum StateMinimum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N.
1妤垫渶灏忕煭绲¢浕娴闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺N闁撱伄1妤垫渶灏忕煭绲¢浕娴併
ShortCircuit1PolePowerFactorMinimumState P_SINGLEVALUE / IfcReal
Short Circuit1 Pole Power Factor Minimum StatePower factor of the minimum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N.
1妤垫渶灏忕煭绲¢浕娴佸姏鐜闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺N闁撱伄1妤垫渶灏忕煭绲¢浕娴佸姏鐜囥
EarthFault1PoleMaximumState P_SINGLEVALUE / IfcElectricCurrentMeasure
Earth Fault1 Pole Maximum StateMaximum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN.
1妤垫渶澶у湴绲¢浕娴闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺PE/PEN闁撱伄1妤垫渶澶у湴绲¢浕娴併
EarthFault1PolePowerFactorMaximumState P_SINGLEVALUE / IfcReal
Earth Fault1 Pole Power Factor Maximum StatePower factor of the maximum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN.
1妤垫渶澶у湴绲¢浕娴佸姏鐜闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺PE/PEN闁撱伄1妤垫渶澶у湴绲¢浕娴佸姏鐜囥
EarthFault1PoleMinimumState P_SINGLEVALUE / IfcElectricCurrentMeasure
Earth Fault1 Pole Minimum StateMinimum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN.
1妤垫渶灏忓湴绲¢浕娴闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺PE/PEN闁撱伄1妤垫渶灏忓湴绲¢浕娴併
EarthFault1PolePowerFactorMinimumState P_SINGLEVALUE / IfcReal
Earth Fault1 Pole Power Factor Minimum StatePower factor of the minimum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN.
1妤垫渶灏忓湴绲¢浕娴佸姏鐜闆绘簮渚涚郸鏅傜偣銇偣1鐩搞仺PE/PEN闁撱伄1妤垫渶灏忓湴绲¢浕娴佸姏鐜囥