6.3.4.10 Pset_FastenerWeld

PSET_TYPEDRIVENOVERRIDE / IfcFastener / WELD

Natural language names
Fastener Weld
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
Type1 P_SINGLEVALUE / IfcLabel
Type1Type of weld seam according to ISO 2553. Note, combined welds are given by two corresponding symbols in the direction of the normal axis of the coordinate system. For example, an X weld is specified by Type1 = 'V' and Type2 = 'V'.
Type2 P_SINGLEVALUE / IfcLabel
Type2See Type1.
Surface1 P_SINGLEVALUE / IfcLabel
Surface1Aspect of weld seam surface, i.e. 'plane', 'curved' or 'hollow'. Combined welds are given by two corresponding symbols analogous to Type1 and Type2.
Surface2 P_SINGLEVALUE / IfcLabel
Surface2See Surface1.
Process P_SINGLEVALUE / IfcInteger
ProcessReference number of the welding process according to ISO 4063, an up to three digits long code
ProcessName P_SINGLEVALUE / IfcLabel
Process NameName of the welding process. Alternative to the numeric Process property.
a P_SINGLEVALUE / IfcPositiveLengthMeasure
aMeasure a according to ISO 2553
c P_SINGLEVALUE / IfcPositiveLengthMeasure
cMeasure c according to ISO 2553
d P_SINGLEVALUE / IfcPositiveLengthMeasure
dMeasure d according to ISO 2553
e P_SINGLEVALUE / IfcPositiveLengthMeasure
eMeasure e according to ISO 2553
l P_SINGLEVALUE / IfcPositiveLengthMeasure
lMeasure l according to ISO 2553
n P_SINGLEVALUE / IfcCountMeasure
nCount n according to ISO 2553
s P_SINGLEVALUE / IfcPositiveLengthMeasure
sMeasure s according to ISO 2553
z P_SINGLEVALUE / IfcPositiveLengthMeasure
zMeasure z according to ISO 2553
Intermittent P_SINGLEVALUE / IfcBoolean
IntermittentIf fillet weld, intermittent or not
Staggered P_SINGLEVALUE / IfcBoolean
StaggeredIf intermittent weld, staggered or not

Link to this page  Link to this page