7.4.4.80 Pset_TransformerTypeCommon

PSET_TYPEDRIVENOVERRIDE / IfcTransformer

Natural language names
Transformer Type Common
Properties

buildingSMART Data Dictionary

PSD-XML

NameTypeDescription
Reference P_SINGLEVALUE / IfcIdentifier *
BauteiltypBezeichnung zur Zusammenfassung gleichartiger Bauteile zu einem Bauteiltyp (auch Konstruktionstyp genannt). Alternativ zum Namen des "Typobjekts", insbesondere wenn die Software keine Typen unterst眉tzt.
ReferenceReference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types.
ReferenceR茅f茅rence 脿 l'identifiant d'un type sp茅cifi茅 dans le contexte du projet (exemple : "type A1") pour d茅signer un "type de construction". Une alternative au nom d'un objet type lorsque les objets types ne sont pas g茅r茅s par le logiciel.
鍙傜収瑷樺彿銇撱伄銉椼儹銈搞偋銈儓銇亰銇戙倠鍙傜収瑷樺彿(渚嬶細A-1)銆傚垎椤炪偝銉笺儔銇с伅銇亸鍐呴儴銇т娇鐢ㄣ仌銈屻倠銉椼儹銈搞偋銈儓銈裤偆銉椼仺銇椼仸浣跨敤銇曘倢銈嬨倐銇
鍙傝冨彿鑻ユ湭閲囩敤宸茬煡鐨勫垎绫荤郴缁燂紝鍒欒灞炴т负璇ラ」鐩腑璇ョ被鍨嬫瀯浠剁殑鍙傝冪紪鍙凤紙渚嬪锛岀被鍨婣-1锛夈
Status P_ENUMERATEDVALUE / IfcLabel / PEnum_ElementStatus*
StatusStatus bzw. Phase des Bauteils insbesondere beim Bauen im Bestand. "Neu" (new) neues Bauteil als Erg盲nzung, "Bestand" (existing) bestehendes Bauteil, dass erhalten bleibt, "Abbruch" (demolish) Bauteil, das abgebrochen wird, "Tempor盲r" (temporary) Bauteil und andere Bauelemente, die vor眉bergehend eingebaut werden (wie Abst眉tzungen, etc.)
StatusStatus of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).
StatutStatut de l'茅l茅ment, principalement utilis茅 dans les projets de r茅novation et de r茅habilitation. Le statut a pour valeur NOUVEAU pour un nouvel 茅l茅ment, EXISTANT pour un 茅l茅ment existant qui est conserv茅, DEMOLI pour un 茅l茅ment existant 脿 d茅molir et TEMPORAIRE pour un 茅l茅ment temporaire (comme une structure support provisoire).
鐘舵厠瑕佺礌锛堜富銇儶銉庛儥銉笺偡銉с兂銇俱仧銇敼淇儣銉偢銈с偗銉堛伀銇娿亜銇︼級銇姸鎱嬨 鐘舵厠銇併屾柊瑕(New)銆嶏紞鏂般仐銇忚拷鍔犮仌銈屻倠瑕佺礌銆傘屾棦瀛樸嶏紞瑕佺礌銇瓨鍦ㄣ仐銆併亱銇ゆ畫銈娿倐銇傘岀牬澹娿嶏紞瑕佺礌銇瓨鍦ㄣ仐銇熴亴銆佸粌妫勩仌銈屻倠銈傘伄銆傘屼竴鏅傜殑銆嶏紞涓鏅傜殑銇瓨鍦ㄣ仚銈嬭绱狅紙涓鏅傜殑銇偟銉濄兗銉堛仐銇︺亜銈嬫閫犮伄銈堛亞銇倐銇級銆
PrimaryVoltage P_SINGLEVALUE / IfcElectricVoltageMeasure
Primary VoltageThe voltage that is going to be transformed and that runs into the transformer on the primary side.
绗1闆诲湩澶夊湩鍣ㄣ伄1娆″伌銇紳閫併仌銈屻倠闆诲湩銆
SecondaryVoltage P_SINGLEVALUE / IfcElectricVoltageMeasure
Secondary VoltageThe voltage that has been transformed and is running out of the transformer on the secondary side.
绗2闆诲湩澶夊湩鍣ㄣ伄2娆″伌銇稿嚭鍔涖仌銈屻倠闆诲湩銆
PrimaryCurrent P_SINGLEVALUE / IfcElectricCurrentMeasure
Primary CurrentThe current that is going to be transformed and that runs into the transformer on the primary side.
绗1闆绘祦澶夊湩鍣ㄣ伄1娆″伌銇紳閫併仌銈屻倠闆绘祦銆
SecondaryCurrent P_SINGLEVALUE / IfcElectricCurrentMeasure
Secondary CurrentThe current that has been transformed and is running out of the transformer on the secondary side.
绗2闆绘祦澶夊湩鍣ㄣ伄2娆″伌銇稿嚭鍔涖仌銈屻倠闆绘祦銆
PrimaryFrequency P_SINGLEVALUE / IfcFrequencyMeasure
Primary FrequencyThe frequency that is going to be transformed and that runs into the transformer on the primary side.
绗紤鍛ㄦ尝鏁澶夊湩鍣ㄣ伄1娆″伌銇紳閫併仌銈屻倠鍛ㄦ尝鏁般
SecondaryFrequency P_SINGLEVALUE / IfcFrequencyMeasure
Secondary FrequencyThe frequency that has been transformed and is running out of the transformer on the secondary side.
绗2鍛ㄦ尝鏁澶夊湩鍣ㄣ伄2娆″伌銇嚭鍔涖仌銈屻倠鍛ㄦ尝鏁般
PrimaryApparentPower P_SINGLEVALUE / IfcPowerMeasure
Primary Apparent PowerThe power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side.
绗1闆诲姏澶夊湩鍣ㄣ伄1娆″伌銇紳閫併仌銈屻倠闆诲姏锛圴A: 銈€兂銉氥偄锛夈
SecondaryApparentPower P_SINGLEVALUE / IfcPowerMeasure
Secondary Apparent PowerThe power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side.
绗2闆诲姏澶夊湩鍣ㄣ伄2娆″伌銇稿嚭鍔涖仌銈屻倠闆诲姏锛圴A: 銈€兂銉氥偄锛夈
MaximumApparentPower P_SINGLEVALUE / IfcPowerMeasure
Maximum Apparent PowerMaximum apparent power/capacity in VA (volt ampere).
鏈澶ч浕鍔鐨浉闆诲姏/瀹归噺 銇渶澶уゃ锛圴A:銈€兂銉氥偄锛夈
SecondaryCurrentType P_ENUMERATEDVALUE / IfcLabel / PEnum_SecondaryCurrentType
Secondary Current TypeA list of the secondary current types that can result from transformer output.
绗2闆绘祦銈裤偆銉澶夊湩鍣ㄣ倛銈婂嚭鍔涖仌銈屻倠绗2闆绘祦銇ó椤炪伄涓瑕с
ShortCircuitVoltage P_SINGLEVALUE / IfcComplexNumber
Short Circuit VoltageA complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %.
鐭怠闆诲湩%銇т笌銇堛倝銈屻倠澶夊湩鍣ㄣ伄瀹氭牸闆绘祦銇亰銇戙倠鐭怠闆诲湩銇疅鏁般仺铏氭暟銈掑畾缇┿仚銈嬭绱犳暟銆
RealImpedanceRatio P_SINGLEVALUE / IfcRatioMeasure
Real Impedance RatioThe ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor.
銈ゃ兂銉斻兗銉銉炽偣瀹熼儴姣旂巼闆剁浉銈ゃ兂銉斻兗銉銉炽偣銇ㄦ鐩搞偆銉炽償銉笺儉銉炽偣锛堜緥锛庣煭绲¢浕鍦с伄瀹熼儴锛夈伄闁撱伄姣旂巼銆侼-銈炽兂銉銈偪銉笺倰鍚個涓夌浉銉堛儵銉炽偣銇仧銈併伀浣跨敤銆
ImaginaryImpedanceRatio P_SINGLEVALUE / IfcRatioMeasure
Imaginary Impedance RatioThe ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor.
銈ゃ兂銉斻兗銉銉炽偣铏氶儴姣旂巼闆剁浉銈ゃ兂銉斻兗銉銉炽偣銇ㄦ鐩搞偆銉炽償銉笺儉銉炽偣锛堜緥锛庣煭绲¢浕鍦с伄铏氶儴锛夈伄闁撱伄姣旂巼銆侼-銈炽兂銉銈偪銉笺倰鍚個涓夌浉銉堛儵銉炽偣銇仧銈併伀浣跨敤銆
TransformerVectorGroup P_ENUMERATEDVALUE / IfcLabel / PEnum_TransformerVectorGroup
Transformer Vector GroupList of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer); The connectivity is only relevant for three-phase transformers.
IsNeutralPrimaryTerminalAvailable P_SINGLEVALUE / IfcBoolean
Is Neutral Primary Terminal AvailableAn indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE).
涓х偣绗1銈裤兗銉熴儕銉亴銇傘倠銇嬨仼銇嗐亱涓娆″坊绶氥伄涓х偣銇屻偪銉笺儫銉娿儷銇牬鍚堛伅锛=TRUE锛夈侀仌銇嗗牬鍚堛伅锛= FALSE锛夈仺銇椼仸琛ㄧず銇欍倠
IsNeutralSecondaryTerminalAvailable P_SINGLEVALUE / IfcBoolean
Is Neutral Secondary Terminal AvailableAn indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE).
涓х偣绗2銈裤兗銉熴儕銉亴銇傘倠銇嬨仼銇嗐亱浜屾宸荤窔銇腑鎬х偣銇屻偪銉笺儫銉娿儷銇牬鍚堛伅锛=TRUE锛夈侀仌銇嗗牬鍚堛伅锛= FALSE锛夈仺銇椼仸琛ㄧず銇欍倠

Link to this page  Link to this page