IFC 4.3.0.0 (IFC4X3) final

7.7.4.6 Pset_FenderDesignCriteria

7.7.4.6.1 Semantic definition

Properties common to the definition of design criteria of all occurrences of IfcImpactProtectionDevice and types of IfcImpactProtectionDeviceType with the predefined type set to FENDER.

7.7.4.6.2 Applicable entities

7.7.4.6.3 Properties

Name Property Type Data Type Description
CoefficientOfFriction IfcPropertySingleValue IfcPositiveRatioMeasure

Coefficient of friction value for the fender

EnergyAbsorptionTolerance IfcPropertySingleValue IfcPositiveRatioMeasure

Manufacturing tolerance on energy absorption

MaxReactionTolerance IfcPropertySingleValue IfcPositiveRatioMeasure

Manufacturing tolerance on maximum reaction at fender support.

MaximumTemperatureFactor IfcPropertySingleValue IfcPositiveRatioMeasure

Deviation in performance due to maximum design temperature

MinimumTemperatureFactor IfcPropertySingleValue IfcPositiveRatioMeasure

Deviation in performance due to minimum design temperature

VelocityFactorEnergy IfcPropertySingleValue IfcPositiveRatioMeasure

Deviation in energy absorption performance due to strain rate

VelocityFactorReaction IfcPropertySingleValue IfcPositiveRatioMeasure

Deviation in reaction due to strain rate

EnergyAbsorption IfcPropertySingleValue IfcEnergyMeasure

Energy absorption capacity of the element.

MaxReaction IfcPropertySingleValue IfcForceMeasure

Maximum reaction from the element

MinCompressedFenderHeight IfcPropertySingleValue IfcPositiveLengthMeasure

Minimum height required for a compressed fender to prevent vessels striking the structure

AddedMassCoefficientMethod IfcPropertyEnumeratedValue PEnum_AddedMassCoefficientMethod

Method used to determine the Added Mass Coefficient used for design

Table 7.7.4.6.A

7.7.4.6.4 Changelog

  • New resource