7.4.4.42 Pset_OutletTypeCommon

7.4.4.42.1 Semantic definition

Common properties for different outlet types.

7.4.4.42.2 Applicable entities

7.4.4.42.3 Properties

Name Property Type Data Type Description
Reference IfcPropertySingleValue IfcIdentifier

Reference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used.

Status IfcPropertyEnumeratedValue PEnum_ElementStatus

Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).

IsPluggableOutlet IfcPropertySingleValue IfcLogical

Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN).

NumberOfSockets IfcPropertySingleValue IfcCountMeasure

The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence.

Table 7.4.4.42.A

7.4.4.42.4 Changelog

  • applicability, IfcOutlet
  • property, NumberOfSockets
  • property, Reference
  • property, Status
  • applicability, IfcOutletType